PEPPOL-EN16931-R004: Specification identifier MUST have the value…

Peppol BIS Billing 3.0.20 · UBL

fatalformat

Original rule text

Specification identifier MUST have the value 'urn:cen.eu:en16931:2017#compliant#urn:fdc:peppol.eu:2017:poacc:billing:3.0'.

Stored validation assertion
starts-with(normalize-space(cbc:CustomizationID/text()), 'urn:cen.eu:en16931:2017#compliant#urn:fdc:peppol.eu:2017:poacc:billing:3.0')

PEPPOL-EN16931-R004 is a fatal rule in the format layer of Peppol BIS Billing 3.0.20 · UBL. An invoice that breaks it is rejected.

Where to go next

PEPPOL-EN16931-R004 changed in 1 published Peppol BIS Billing UBL release comparison:

Validate an invoice against these rules · All release changes